Publikationen


Radiation exposure of the interventional radiologist during percutaneous biopsy using a multiaxis interventional C-arm CT system with 3D laser guidance: a phantom study.

15.09.2015

Rathmann N, Kostrzewa M, Kara K, Bartling S, Haubenreisser H, Schoenberg SO, Diehl SJ. Br J Radiol. 2015 Nov;88(1055):20150151. doi: 10.1259/bjr.20150151. Epub 2015 Sep 15. OBJECTIVE:Evaluation of absolute radiation exposure values for interventional radiologists (IRs) using a multiaxis interventional flat-panel C-arm cone beam CT (CBCT) system with three-dimensional laser guidance for biopsy in a triple-modality,

... weiter lesen

Improving the stability of peptidic radiotracers by the introduction of artificial scaffolds: which structure element is most useful?

27.07.2015

Bacher L, Fischer G, Litau S, Schirrmacher R, Wängler B, Baller M, Wängler C. J Labelled Comp Radiopharm. 2015 Aug;58(10):395-402. doi: 10.1002/jlcr.3315. Epub 2015 Jul 27.  Peptidic radiotracers are highly potent substances for the specific in vivo imaging of various biological targets with Single Photon Emission Computed Tomography and Positron Emission Tomography. However, some radiolabeled

... weiter lesen

Next Step toward Optimization of GRP Receptor Avidities: Determination of the Minimal Distance between BBN(7-14) Units in Peptide Homodimers.

24.07.2015

Fischer G, Lindner S, Litau S, Schirrmacher R, Wängler B, Wängler C. Bioconjug Chem. 2015 Aug 19;26(8):1479-83. doi: 10.1021/acs.bioconjchem.5b00362. Epub 2015 Jul 24.  As the gastrin releasing peptide receptor (GRPR) is overexpressed on several tumor types, it represents a promising target for the specific in vivo imaging of these tumors using positron emission tomography (PET).

... weiter lesen

Accuracy of percutaneous soft-tissue interventions using a multi-axis, C-arm CT system and 3D laser guidance

30.06.2015

Kostrzewa M, Rathmann N, Kara K, Schoenberg SO, Diehl SJ. Eur J Radiol. 2015 Jun 30. pii: S0720-048X(15)30036-X. doi: 10.1016/j.ejrad.2015.06.028. [Epub ahead of print] INTRODUCTION:Purpose of this phantom study was to compare the accuracy of needle placement using a multi-axis, C-arm-based, flat-panel, cone-beam computed tomography system (CBCT guidance) with that under multi-detector computed tomography guidance

... weiter lesen

In Vivo Evaluation of 18F-SiFAlin–Modified TATE: A Potential Challenge for 68Ga-DOTATATE, the Clinical Gold Standard for Somatostatin Receptor Imaging with PET

30.04.2015

Niedermoser S, Chin J, Wängler C, Kostikov A, Bernard-Gauthier V, Vogler N, Soucy JP, McEwan AJ, Schirrmacher R, and Wängler B J Nucl Med. 2015 Jul;56(7):1100-5. doi: 10.2967/jnumed.114.149583. Epub 2015 May 14. Radiolabeled peptides for tumor imaging with PET that can be produced with kits are currently in the spotlight of radiopharmacy and nuclear medicine.

... weiter lesen

From molecular imaging markers to personalized image-guided therapy.

18.01.2013

Schönberg SO, Wängler B. Z Med Phys. 2013 Feb;23(1):1-2. doi: 10.1016/j.zemedi.2012.12.004. Epub 2013 Jan 18. PMID: 23333669 [PubMed – indexed for MEDLINE]