{"id":1960,"date":"2020-04-30T09:41:49","date_gmt":"2020-04-30T07:41:49","guid":{"rendered":"http:\/\/www.m2olie.de\/?post_type=publications&#038;p=1960"},"modified":"2022-10-12T09:42:12","modified_gmt":"2022-10-12T07:42:12","slug":"magnetic-resonance-fingerprinting-for-simultaneous-renal-t1-and-t2-mapping-in-a-single-breath%e2%80%90hold","status":"publish","type":"publications","link":"https:\/\/www.m2olie.de\/en\/publications\/magnetic-resonance-fingerprinting-for-simultaneous-renal-t1-and-t2-mapping-in-a-single-breath%e2%80%90hold\/","title":{"rendered":"Magnetic resonance fingerprinting for simultaneous renal T1 and T*2 mapping in a single breath\u2010hold"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\"><a href=\"https:\/\/onlinelibrary.wiley.com\/action\/doSearch?ContribAuthorStored=Hermann%2C+Ingo\">Ingo Hermann<\/a><a href=\"https:\/\/onlinelibrary.wiley.com\/action\/doSearch?ContribAuthorStored=Chacon-Caldera%2C+Jorge\">, Jorge Chacon\u2010Caldera<\/a><a href=\"https:\/\/onlinelibrary.wiley.com\/action\/doSearch?ContribAuthorStored=Brumer%2C+Ir%C3%A8ne\">, Ir\u00e8ne Brumer<\/a><a href=\"https:\/\/onlinelibrary.wiley.com\/action\/doSearch?ContribAuthorStored=Rieger%2C+Benedikt\">, Benedikt Rieger, <\/a><a href=\"https:\/\/onlinelibrary.wiley.com\/action\/doSearch?ContribAuthorStored=Weing%C3%A4rtner%2C+Sebastian\">Sebastian Weing\u00e4rtner, <\/a><a href=\"https:\/\/onlinelibrary.wiley.com\/action\/doSearch?ContribAuthorStored=Schad%2C+Lothar+R\">Lothar R. Schad, <\/a><a href=\"https:\/\/onlinelibrary.wiley.com\/action\/doSearch?ContribAuthorStored=Z%C3%B6llner%2C+Frank+G\">Frank G. Z\u00f6llner<\/a><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Magnetic Resonance in Medicine, 83(6):1940-1948, 2020<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">First published: 03 January 2020<\/p>\n\n\n\n<p>First published: 03 January 2020 <a href=\"https:\/\/doi.org\/10.1002\/mrm.28160\">https:\/\/doi.org\/10.1002\/mrm.28160 <span><a style=\"vertical-align: text-bottom\" href=\"\"><\/a><\/span><\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"d38008855\">Abstract<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"mrm28160-sec-0001-title\">Purpose<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">To evaluate the use of magnetic resonance fingerprinting (MRF) for simultaneous quantification of <img decoding=\"async\" alt=\"urn:x-wiley:07403194:media:mrm28160:mrm28160-math-0005\" src=\"https:\/\/onlinelibrary.wiley.com\/cms\/asset\/6a95b8cb-feb2-4fd2-a266-fd3617d63046\/mrm28160-math-0005.png\"> and <img decoding=\"async\" alt=\"urn:x-wiley:07403194:media:mrm28160:mrm28160-math-0006\" src=\"https:\/\/onlinelibrary.wiley.com\/cms\/asset\/d51f6e67-42f9-48ec-8973-0144eea19058\/mrm28160-math-0006.png\"> in a single breath\u2010hold in the kidneys.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"mrm28160-sec-0002-title\">Methods<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The proposed kidney MRF sequence was based on MRF echo\u2010planar imaging. Thirty\u2010five measurements per slice and overall 4 slices were measured in 15.4&nbsp;seconds. Group matching was performed for in\u2010line quantification of <img decoding=\"async\" alt=\"urn:x-wiley:07403194:media:mrm28160:mrm28160-math-0007\" src=\"https:\/\/onlinelibrary.wiley.com\/cms\/asset\/d6f9c37a-dab6-4945-82df-c8a0f94a2563\/mrm28160-math-0007.png\"> and <img decoding=\"async\" alt=\"urn:x-wiley:07403194:media:mrm28160:mrm28160-math-0008\" src=\"https:\/\/onlinelibrary.wiley.com\/cms\/asset\/25af5a07-a250-4340-9db7-dd28ce4c6d44\/mrm28160-math-0008.png\">. Images were acquired in a phantom and 8 healthy volunteers in coronal orientation. To evaluate our approach, region of interests were drawn in the kidneys to calculate mean values and standard deviations of the <img decoding=\"async\" alt=\"urn:x-wiley:07403194:media:mrm28160:mrm28160-math-0009\" src=\"https:\/\/onlinelibrary.wiley.com\/cms\/asset\/6003f561-7b4b-4fc8-9fef-bd75a67567a1\/mrm28160-math-0009.png\"> and <img decoding=\"async\" alt=\"urn:x-wiley:07403194:media:mrm28160:mrm28160-math-0010\" src=\"https:\/\/onlinelibrary.wiley.com\/cms\/asset\/4fd14cb5-4d20-4709-af07-791f912b7132\/mrm28160-math-0010.png\"> times. Precision was calculated across multiple repeated MRF scans. Gaussian filtering is applied on baseline images to improve SNR and match stability.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"mrm28160-sec-0003-title\">Results<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><img decoding=\"async\" alt=\"urn:x-wiley:07403194:media:mrm28160:mrm28160-math-0011\" src=\"https:\/\/onlinelibrary.wiley.com\/cms\/asset\/c25e6507-ecee-4e84-b9a2-969f8f3fb819\/mrm28160-math-0011.png\"> and <img decoding=\"async\" alt=\"urn:x-wiley:07403194:media:mrm28160:mrm28160-math-0012\" src=\"https:\/\/onlinelibrary.wiley.com\/cms\/asset\/f8c4a4f7-506f-417e-8f3d-0c62845aadfe\/mrm28160-math-0012.png\"> times acquired with MRF in the phantom showed good agreement with reference measurements and conventional mapping methods with deviations of less than 5% for <img decoding=\"async\" alt=\"urn:x-wiley:07403194:media:mrm28160:mrm28160-math-0013\" src=\"https:\/\/onlinelibrary.wiley.com\/cms\/asset\/59240701-4daa-4fc8-b2e3-e39ef05b826d\/mrm28160-math-0013.png\"> and less than 10% for <img decoding=\"async\" alt=\"urn:x-wiley:07403194:media:mrm28160:mrm28160-math-0014\" src=\"https:\/\/onlinelibrary.wiley.com\/cms\/asset\/6521c3f3-83c1-4246-8764-77cb0dfc4b17\/mrm28160-math-0014.png\">. Baseline images in vivo were free of artifacts and relaxation times yielded good agreement with conventional methods and literature (deviation <img decoding=\"async\" alt=\"urn:x-wiley:07403194:media:mrm28160:mrm28160-math-0015\" src=\"https:\/\/onlinelibrary.wiley.com\/cms\/asset\/e0bac5c2-876d-44a2-9b58-0d5a3edb0e09\/mrm28160-math-0015.png\">, <img decoding=\"async\" alt=\"urn:x-wiley:07403194:media:mrm28160:mrm28160-math-0016\" src=\"https:\/\/onlinelibrary.wiley.com\/cms\/asset\/63786d65-bc0d-4d80-8aa4-b9f6810fcb46\/mrm28160-math-0016.png\">).<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"mrm28160-sec-0004-title\">Conclusions<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">In this feasibility study, the proposed renal MRF sequence resulted in accurate <img decoding=\"async\" alt=\"urn:x-wiley:07403194:media:mrm28160:mrm28160-math-0017\" src=\"https:\/\/onlinelibrary.wiley.com\/cms\/asset\/4ee4fd75-0bdd-40fb-b2a2-8ee9a5bce26d\/mrm28160-math-0017.png\"> and <img decoding=\"async\" alt=\"urn:x-wiley:07403194:media:mrm28160:mrm28160-math-0018\" src=\"https:\/\/onlinelibrary.wiley.com\/cms\/asset\/0e4c939e-d10f-4dc3-85d2-b1b09646307d\/mrm28160-math-0018.png\"> quantification in a single breath\u2010hold.<\/p>\n","protected":false},"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"categories":[],"class_list":["post-1960","publications","type-publications","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.m2olie.de\/en\/wp-json\/wp\/v2\/publications\/1960","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.m2olie.de\/en\/wp-json\/wp\/v2\/publications"}],"about":[{"href":"https:\/\/www.m2olie.de\/en\/wp-json\/wp\/v2\/types\/publications"}],"replies":[{"embeddable":true,"href":"https:\/\/www.m2olie.de\/en\/wp-json\/wp\/v2\/comments?post=1960"}],"version-history":[{"count":2,"href":"https:\/\/www.m2olie.de\/en\/wp-json\/wp\/v2\/publications\/1960\/revisions"}],"predecessor-version":[{"id":3365,"href":"https:\/\/www.m2olie.de\/en\/wp-json\/wp\/v2\/publications\/1960\/revisions\/3365"}],"wp:attachment":[{"href":"https:\/\/www.m2olie.de\/en\/wp-json\/wp\/v2\/media?parent=1960"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.m2olie.de\/en\/wp-json\/wp\/v2\/categories?post=1960"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}